Zelan Construction |
BEC (M) successfully designs & builds two (2) 42m high 6000m3 Fly Ash storage silos
|
|
| :: Completed Silos -Tanjung Bin Power Station, Johor, Malaysia (2004- 2005) :: |
| |
| BEC (M) was appointed by Zelan Holdings (M) Sdn Bhd to design and build the 200m high 3-flue chimney for the 3 x 700MW Coal Fired Power Plant at Tanjung Bin, Johor, Malaysia.
|
 |
CHIMNEY DATA |
Height |
: |
200m |
No. of internal steel flues |
: |
3 |
No. of internal platforms |
: |
3 |
Diameter of internal flues |
: |
7.5m |
External concrete diameter |
: |
23m - 22.5m |
Piles |
: |
60No. x 50m deep |
Pile-cap |
: |
31.4m diameter x 2.5m deep |
| |
|
| |
|
|
|
|
|
|
Shell Refining Company |
| |
|
|
:: Shell’s Pulau Bukom Refinery– currently Shell’s largest refinery in the world ::
|
| |
| In 2004 BEC (S) were awarded the contract to design and build a new 100m high 3-flue chimney for the existing and future Sulphur Recovery Units on Shell’s Pulau Bukom refinery. |
| |
|
|
|
CHIMNEY DATA |
Height |
: |
100m |
No. of internal steel flues |
: |
3 |
No. of internal platforms |
: |
3 |
Diameter of internal flues |
: |
1.05m |
External concrete diameter |
: |
6.3m - 6m |
Piles |
: |
24No. x 356x356x134kg/m |
Pile-cap: |
: |
10.1m diameter x 2.0m deep |
|
|
|
|
 |
Shell Refining Co. (FOM) Bhd. shutdowns . Port Dickson refinery
Stack: MVU, Plat 2, CD2, LRCCU
Successfully completed inspections and repairs to the above stacks during plant shutdowns. Emergency repairs required due to emergent works during inspection. |
|
| |
|
|
| |
 |
Shell Eastern Petroleum Pte Ltd |
|
 |
Shell Eastern Petroleum Pte. Ltd. shutdowns. Pulau Bukom refinery
Stacks: CD3, CD4, CD5, HCU, LRCCU, HCS, HCSII, TGU
Successfully completed inspection and repairs to the above stacks during plant shutdowns.
Works involved major and minor repairs to brick, steel and refractory linings. |
| |
Shell Eastern Petroleum Pte. Ltd. LOC/UTL shutdown
This project involves the design and construction of a steel liner. The liner is to be installed inside the existing windshield replacing the existing brick liner. |
| |
New design & build SRU Stack
BEC (S) successfully completes from feasibility studies through to conceptual design and final construction the new 100m high SRU stack servicing SRU units 3 & 5 and future SRU 6 unit. |
| |
| Email us at sales@be-con.com should you require a copy of the Project Report |
|
| |
|
| |
|
|
| |
OTHER PROJECTS |
• |
ALSTOM Power Asia Pacific Sdn Bhd.
Perlis Power Station Pipe Cleaning Cleaned approx. 600m of gas supply pipeline using the rotor fan high-pressure water system.
|
• |
Seraya Power Ltd.
Cleaning and inspection to chimney liners This project involves the phased cleaning and inspection work to four (4) x 180 meter high steel liners. Ultrasonic testing, verticality readings and welding tests are involved to check the integrity of the existing liners.
|
• |
Blue Circle Materials Silo alterations Site managing the repairs and alterations on two 66m high bulk storage silos in Jurong Port.